序號 NO. |
UWV
參數名稱Parameters |
i1VuI |
UC |
產品代號Product code |
ZJ400S系列series |
1 |
線圈額定電壓Rated coil volt (V DC) |
12 |
24 |
30 |
48 |
60 |
72 |
120 |
2 |
20℃冷態起動線圈最大電流Max.coil start current in cold state at 20℃(A) |
7.5 |
5 |
3.8 |
2.4 |
1.8 |
1.6 |
1 |
3 |
20℃額定電壓下線圈維持電流keep the coil current under rated volt at 20℃(A) |
0.7 |
0.4 |
0.3 |
0.3 |
0.2 |
0.2 |
0.1 |
4 |
線圈功耗Coil Power dissipation(W) |
6~10 |
5 |
(20±5)℃下,冷態動作電壓Operating volt in cold state at (20±5)℃(V) |
吸合Pick-up |
不大于線圈額定電壓的70% Not above70%of rated coil volt |
釋放Release |
線圈額定電壓的(5~40)% Rated coil volt(5~40)% |
6 |
電源電壓波動范圍Fluctuating range of power supply volt |
(85%~110%)額定電壓 (85%~110%)rated volt |
7 |
主觸點電路額定電壓Rated volt of contact circuit(V DC) |
60 VDC |
8 |
主觸點電路額定負載電流Rated load current of contact circuit(A) |
400A |
9 |
100A負載下主觸點接觸壓降Contact volt drop of contact at 50A: |
≤50mV |
10 |
主觸點最大通斷能力Max .make-break ability of contact |
通斷1次4倍額定負載電流,通電時間 (Connect four times rated load current, make and break once for )5ms |
11 |
額定電壓下最大動作時間 (mS) Max.operating time at rated volt(ms) (coil with no suppression circuit) |
吸合Pick-up |
30 mS |
釋放Release |
30 mS |
12 |
觸點最大彈跳時間Max.bounce times when contact breaks(mS) |
3 mS |
13 |
抗電強度Puncture(volt)strength |
50Hz,1000V AC,1min |
14 |
電壽命Electric life(r=0.001S)(次) (cycles) |
50,000 |
15 |
機械壽命Mechanical life |
100.000次Ops |
16 |
工作規范Working duty |
連續Continuous |